Re: LRM 2.3.1 Draft C posted

From: David Miller <David.L.Miller_at_.....>
Date: Thu Feb 26 2009 - 07:01:13 PST
Yes, I have an action item to create a table for changes from 2.3 to 2.3.1

Cheers...
Dave

Geoffrey.Coram wrote:
> Do we need a new section in Annex G, on the changes from previous LRMs?
> 
> -Geoffrey
> 
> 
> 
> David Miller wrote:
>> http://www.eda-stds.org/verilog-ams/htmlpages/public-docs/v2.3.1_drafts/VAMS-LRM-2-3-1-Draft-C.pdf 
>>
>>
>> The following was addressed:
>>
>>> #2581 - 3.12 - Last sentence in paragraph 3 should read:
>>>
>>> There shall be at most one unnamed branch between any two nets or 
>>> between a net
>>> and implicit ground (in addition to any number of named branches).
>>>
>>> * 5.4.1 - Example 2 sub point 1. Last sentence should read:
>>>
>>> There can only be one unnamed branch between any two nets or between 
>>> a net and
>>> implicit ground (in addition to any number of named branches).
>>>
>>> #2266 - D.1 - for the signal flow current it should be current 
>>> Current not
>>> potential Current.
>>>
>>> # MISC - at the start of the grammar, add the sentence:
>>> The following grammar is designed as a presentation grammar and 
>>> should not be
>>> interpreted as an unambiguous production grammar. The compiler 
>>> developer will be
>>> required to implement the various semantic restrictions outlined 
>>> through out
>>> this reference manual to remove any ambiguities.
>>>
>>> # 2537 - Sub issue 7 - 6.4(.1)/A.1.9 - the 
>>> .module_parameter_identifier and
>>> .system_parameter_identifier should be assigned a 
>>> paramset_constant_expression.
>>> A paramset_constant_expression is a constant_expression minus the 
>>> reference to
>>> parameters. The production should look like:
>>>
>>> paramset_constant_expression ::=     constant_expression
>>>   | hierarchical_parameter_identifier
>>>
>>>
>>> In 6.4.1 - the sentence should read:
>>> The expression on the right-hand side can be composed of numbers , 
>>> parameters
>>> and hierarchical out-of-module references to local parameters of a 
>>> different
>>> module. Hierarchical out-of-module references to non-local parameters 
>>> of a
>>> different module is disallowed.
>>>
>>> Also declare electrical gnd and replace reference to 0 with gnd in 
>>> example
>>> 6.4.1
>>
>> Issue 2497 /#13 analysis() function still needs to be addressed and I 
>> hope to have that done before the call tomorrow.
>>
>> Dave
>>
> 
> 

-- 
==============================================
-- It's a beautiful day
-- Don't let it get away
--
-- David Miller
-- Design Technology (Austin)
-- Freescale Semiconductor
-- Ph : 512 996-7377 Fax: x7755
==============================================

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Thu Feb 26 07:03:31 2009

This archive was generated by hypermail 2.1.8 : Thu Feb 26 2009 - 07:03:40 PST