The Configuration Problem Solver

Address Pins don't start at 000000h.

    To configure in the Master Parallel Mode the Mode Pins <M2:M1:M0> must be set to <100> for Parallel Up Mode, and <110> for Parallel Down Mode. In the Parallel Up Mode the Address lines start at <00000h> and count up. In the Parallel Down Mode the Address lines start at <1FFFFh> and count down.

    Be certain that the PROM data was stored properly for the selected MODE.

HISTORY
Family: XC3000
Mode: Master Parallel
D/P: LOW
INIT: HIGH
ADD: YES
LDC: LOW